R&D

Our R&D laboratory’s final aim is to design redunded fault-tolerant systems at each level foreseeing hardware Hot-Swap criteria, automatic system updates, tested software and design solutions, online self-monitoring and diagnostics systems, disk-less controller.

All these Developments verified through:

FMEA Failure Mode & Effects analisys

MTBF (mean time between failures)

Hands-on and continuous staff-training

Direct and wrapped continuous interface with Class Registers

Moreover, MASSO IND precedes all Laboratory test, supporting itself with a customized software (MIST) designed by our engineers.

MIST can configure and set the cards housed in the system in order to work in “Automation check” ; this state is also thought in stage of commissioning and for this “commissioning mode” the configuration upload lasts 20 seconds, same time needed to refresh the card in normal operation mode.

As MIST is directly connected to the farthest field device, Customer can simulate each command towards our system, operating and monitoring its real state and eventual warnings/alarms . ; all receipts of feedback, controllable also by Service Terminal, are virtual. Each moving timetable seconds it checks the correctness of the unit during opening and closing command.

This software is also able to “stress” a unit, giving it first opening command and then closing command with a settable timetable from 1 minute up to 2 seconds; this operation is useful for testing the inertial consumption.

MASSO IND works in strict compliance with following Normes according to IEC 60092-504 ED 3.0 and IACS req. 1991/Rev.5 2006 - E10 Test specification for type approval:

IEC60068-2-2 – Dry Heat

IEC60068-2-30 – Test Db - Damp Heat

IEC60068-2-6 – Test Fc - Vibration

IEC 60092-504 – Inclination

IEC 60068-2-1 – Test Ab and Ad – Cold

IEC 60068-2-52 – Test Kb – Salt mist

IEC 61000-4-2 – Electrostatic discharge

IEC 61000-4-3 – Electromagnetic field

IEC 60533 – Conducted low frequency

IEC 61000-4-6 – Conducted Radio Frequency

IEC 61000-4-4 – Burst/Fast Transient

IEC 61000-4-5 – Surge/Voltage

CISPR 16-1, 16-2 – Radiated Emission

CISPR 16-1, 16-2 – Conducted Emission

IEC 60529 – Enclosure Degrees of protection

IEC 60331-21 – Fire Resistance

NAV-30-A001 – Anti-Shock