FIELD DEVICES with embedded electronic

E-ACT-C



E-ACT-C interacts with Adaptive Distribute Control Systems - Cross link technology ( ADCS-C ) and manages a multipurpose Self-contained oil micro Power Unit ( SPU ) as farthest field-device for positioning, sensing and tasking of quarter turn or linear, single or double acting hydraulic actuators or cylinders. Suitable for configuration with direct analog or digital hall-effect FeedBacK Sensors ( FBKS ), VOLumetric OIL sensors ( VOLOIL ) or separated positioning units, each SPU is joined to an IP 68 and FIRE RESISTANT Junction Box ( E-ACT-C-JB ) where the embedded Custom Control Unit ( E-ACT-C-CU ), with ARM® Cortex™- M 32-bit processors and real time operating system matched with two Terminal Boards ( E-ACT-C-TB ), satisfies any casualty event under Safe Return to Port ( SRtP ) Rules. Executions selection between different pump capacities, pressures range and among Fail Set (FS), Fail Close (FC) or Fail Open (FO) assures any safety condition for automatic and immediate positioning in case of power failures. Supplied in different versions according to safe, dry, hazardous or submerged areas.

  • Fully complies with Rules regarding “Safe Return to Port” (IMO Circ. 1214)
  • Integrated control electronics and operative intelligence
  • Suitable for direct FeedBacK Sensors (FBKS), VOLumetric OIL sensors (VOLOIL) or separated positioning units
  • Operable from two CROSS LINK Control Cabinets housed in different vertical fire zones
  • Cross network connection, strongly reducing installation costs
  • Redundant wire connection (power and bus) to avoid any single failure
  • It is a stand-alone mini-system able to self-prevent, control, monitor and diagnostic
  • Provided with n° 3 independent IP68 watertight compartments for cable inlet and electronic housing
  • Provided with n° 2 independent fire resistant compartments for cable inlet
  • Losing a single E-ACT-C, the other units connected in the same cross network are not jeopardized
  • Possibility of local control of a unit, avoiding it directly from the upper control posts.
  • Provided with a local position Led indicator
  • E-ACT-C installation in any possible position
  • VERSIONS FAIL SET - FAIL CLOSE - FAIL OPEN
  • IP 68 protection, 30mt/72 hours
Description Values
Power Supply Redundant 230 Vac 50-60 Hz
Electronic Consumption 5 W
Electric motor consumption 400 W
Max Starting Current 2.3 A
Operating ambient temperature +5 to +55 °C
Max. Ambient Temperature 70°C
Min. Ambient Temperature 5 °C
System Interface Redundant BUS RS 485
E-ACT-C Connected in parallel For reasons of current limitation and voltage drop. You should not connect more than 16 units. If it is necessary to overcome this limit, must be evaluated case by case. In any case the maximum number of units connected in parallel is 31.RS485 insulated
Contemporaneity of command On a line 100 meters long, can simultaneously
command 8 units.
Local interface
  • Hand pump
  • Keyboard for local control
  • Wireless for service and maintenance
  • Interface to ELI (Extended Local Interface)
Design pressure 150 bar
Max. working pressure 150 bar
Test Pressure 225 bar
Recommended Oil Mineral Oil HLP
Oil Viscosity Index ISO Grade 46
Oil Filtration ≤ 10 Micron
Enclosure Area 1 IP68
Area 2 IP68 and Fire Resistant
Area 3 IP68 and Fire Resistant
(IP 68 is 3 bar for 72 Hours)
Cable entry Are installed 4 cable glands for a cable diameter from 16 to 20.5 mm. Are also supplied as accessories for cable diameters from 12.5 to 16 mm
Software update and config. with software MASSO IND MIST
Approvals IEC 60092-504 ED 3.0
IACS E10 Rev.5